RegFlo Pressure and Flow Instruments

RegFlo RF100 Series Pressure and Flow Instruments
RegFlo RF100 Series pressure and flow instruments are devices which measure and archive flow and pressure data. Other parameters such as battery voltage, and minimum and maximum values are also stored. Alarms may be configured to signal abnormal or emergency conditions. The Type RF110 instrument is used as a standalone pressure instrument. Mounted on a regulator, such as the Type EZR, the Type RF100 instrument measures pressure and also estimates flow rates based on valve plug travel.
RegFlo Facts
RegFlo: Fluid Handling and Fluid Power (Mechanical Engineering)
RF100 Flow Recorder
The RegFlo Type RF100 instrument measures valve plug travel, inlet pressure, and outlet pressure. A third pressure sensor is available as an option to measure an additional auxiliary pressure. An algorithm estimates the flow through the regulator and archives pressure, travel, and flow data in history. It also records other parameters such as battery voltage, minimums and maximum values, etc. Alarms may be configured to signal abnormal or emergency conditions.
RF110 Electronic Pressure Recorder (EPR)
The RegFlo Type RF110 Instrument is used as a standalone pressure recorder. It is the same as the Type RF100 except it is mounted remotely from the regulator and does not measure regulator travel or estimate flow rates. Pressures are piped to the unit and are measured and archived in history. Up to 3 pressure sensors may be installed. Other parameters such as battery output, and minimum and maximum values are also stored. Alarms may be configured to signal abnormal or emergency conditions
Features
- Data Archive
- Flow Estimation
- Pressure Recorder
- User Level Security
- Economical Flow Data
- Host Communications
- Local Communications
- Low Power Consumption
- Type EZR Retrofit Capability
Security
- 5 users with passwords and 3 levels of access
Alarms
- Hi, Hi/Hi, Low, and Low/Low, on all analog inputs
- Logic Alarms
- 240 logs in alarm log
Flow Estimation Accuracy
- +/- 20% of actual flow for flow between 10 and 20% of maximum
- +/- 10% of actual flow for flow between 20 and 100% of maximum
Daily Log
- 35 days of daily values (average, accum, min/max)
Sample Intervals
- 10 and 30 seconds; 1, 2, 5, 10, and 30 minutes
Processor Memory
- Flash: 128 Kbytes
- EEProm: 32 Kbytes
- Static RAM: 128 Kbytes
Power
- Battery Input: 3.6 Vdc
- Input Power: 10 to 28 Vdc
Real Time Clock
- Hr : Min : Sec
- Day : Month : Year
- Battery Backed
Diagnostics
- Board Temperature, Power Input, Logic/Battery Voltage
Communication Ports
- Operator Interface: RS-232 (RX, TX, RTS); ROC protocol only
- COM1: RS-485; ROC and ModBus protocol
- COM2 (Optional): RS-232 or V-22 BIS Modem; ROC and ModBus protocol
Approvals
- CSA Class 1, Division 1, Explosion-Proof, Gas Groups C and D; Class 1, Division 2, Nonincindive Groups C and D; Certified to Canadian and U.S. Standards